The statutory role of the Public Analyst’s Laboratory is to test food for compliance with the relevant legislation and guidelines. The laboratory has a vital role in food safety by providing objective scientific evidence for the safety and quality of the food that we eat. It provides data for the proper risk assessment and risk analysis of food.

The Dublin Public Analyst’s Laboratory (PALD) is administered by the HSE Dublin Mid-Leinster. It is one of the laboratories of the Health Service Executive (HSE) Food Safety Laboratory Service (FSLS) which comprises three Public Analyst Laboratories and seven Official Food Microbiology Laboratories, one of which is located at and is an integral part of PALD.   HSE Food Safety Laboratories

The beginning of 2006 marked a significant milestone for food safety in the EU with the entry of a large updated body of food and feed legislation. Primary amongst these is the food hygiene package. Regulation 2073/2005 on microbiological criteria for foodstuffs also came into force at the beginning of 2006.

EU Regulation 178/2002 lays down the general principles and requirements of food law and procedures in matters of food safety. It also established the European Food Safety Authority.

The European Commission package of food hygiene law harmonises and simplifies previously overly complex hygiene requirements. The package consists of five major pieces of legislation covering areas including the hygiene of foodstuffs and specific hygiene rules for food of animal origin. "EU Regulation 882/2004 on official controls performed to ensure the verification of compliance with feed and food law, animal health and animal welfare rules" describes in detail how the principles in Regulation 178/2002 must be interpreted and implemented. From the 1st January 2006 Regulation 882/2004 repealed a number of previous Food Control Acts.

Regulation 882/2004 is currently under revision by the European Commission.

Sampling & Analysis Programmes

This laboratory performs a wide range of testing:

Microbiological Testing

Chemical Testing

The National Chemical Food Sampling and Analysis Programme incorporates a broad range of parameters including mycotoxins, other natural contaminants, heavy metals and other food processing contaminants, food contact materials, food additives and flavourings and some quality parameters.

Dublin PAL is the specialised laboratory for a extensive range of tests that are available on a National basis, including mycotoxins, food contact materials and PAH testing. A wide range of non-specialised tests is also available. Environmental Health Officers (EHOs) from EHS offices in the four HSE Regions (Dublin Mid Leinster, Dublin North East, South and West) and also Officers from other agencies sample a variety of foods at different sampling points including manufacturing, distribution, retail, catering and port and submit them to the laboratory for testing.

Where legislation exists for a parameter, the samples are checked for compliance with a statutory limit. Some of the sampling and analysis is performed as part of monitoring and risk assessment of food safety issues that may have emerged more recently. Such test results may be used in the setting of statutory limits in future legislation.

Back to Top

The discovery of new contaminants in food, together with new regulations or lower regulatory limits for existing food additives and contaminants, means that there is a need to research and develop reliable and robust analytical methods required for survey and enforcement purposes. The chemistry Method Research and Development (MR&D) Section implements new methods of analysis, extends existing methods to new matrices and examines new analytical techniques. The MR&D Section regularly uses the expertise and personnel from other laboratory Sections to achieve these aims.    

Laboratory Contact for Chemical MR&D:    Mr. Chris Griffin.   

The laboratory is currently developing methods of analysis for the speciation of Arsenic, Mercury, Selenium and Tin. The bioavailability and/or toxicity of these, and other, metals are dependent on the form or species in which they exist. The quantification of the individual metal species in foods is vital in risk assessment. In 2006 a PerkinElmer Elan DRC II ICP-MS, a PerkinElmer Series 200 HPLC and a Perkin Elmer Clarus 500 GC were installed as part of the development programme.

Please note that tests are developed / validated in specific food types which predominantly reflect the statutory requirements.    Individual tests are not available in all foodstuffs.

Requirements for the submission of food samples for routine chemical testing

1. Please refer to the National Chemical Food Sampling Programme for information on the types of samples and minimum sample quantities required for each parameter.

2. Food samples submitted for monitoring compliance with EU food laws must be sampled in compliance with the appropriate EU sampling regulation where available.

3. If a number of units of a product are required to make up the required quantity of sample, please ensure that all units are of one batch number. Prior to analysis, all units of the sample are combined and sub-samples are tested. In the event of a non-compliant result being obtained, it is not possible to identify the problematic batch where a composite sample of units from different batches has been tested.

4. When attaching adhesive labels to samples ensure that information such as ingredient lists, nutrition labelling, claims etc. is not obscured.  If the sample is small in size and this is not practical, the sample may be placed in a clear plastic bag to which the label can be attached.

5. It is a requirement of the laboratory accreditation to "ISO 17025:2005 – General Requirements for the Competence of Testing and Calibration Laboratories", that there is a contract between a customer and the laboratory. The National Sample Submission Form is such a contract.  For this reason, it is a requirement that the field "Test(s) Required Chemical" is completed on the form and that the required parameter(s) are specified as indicated in the programme. Entries such as "chemical" or "compositional" analysis are not sufficient. 

6. Please ensure that all samples for chemical testing reach the Laboratory before 3 p.m. on the day of delivery.

7. In the event that scheduled samples cannot be submitted for testing, please inform the specified laboratory contact as soon as possible so that the laboratory resources can be reallocated to other work.

8. Laboratory contact details are provided in the Programme and also in the ‘Contact Us’ section of this website. Please phone or e-mail the appropriate named contact with queries regarding test parameters or sampling.

9. When querying a test result, the Executive Analytical Chemist who is named on the test report should be contacted.

 

Food Samples for Microbiological Testing

Back to Top

  1. Food samples which would normally be refrigerated should be stored in a refrigerator immediately and submitted to the Laboratory within 24h.
  2. Samples which would normally be refrigerated and which cannot be submitted to the Laboratory within 24h should be frozen and submitted as soon as possible thereafter.
  3. All samples must be accompanied by a fully completed Laboratory Analysis Request Form.
  4. All samples should be minimally handled prior to receipt at the Laboratory. The history of sample handling and storage may affect the microbiological results.
  5. A minimum of 150g of food sample is required for microbiological analysis.

 

Storage of samples for microbiological analysis

Back to Top

  1. Frozen foods should be frozen.
  2. Chilled/refrigerated foods should be stored between 0 and 5oC and not frozen.
  3. Dried foods, un-blown cans and foods not generally refrigerated need not be chilled but should be stored and transported at a temperature of less than 20oC

List of microbiological tests

Back to Top

Test

Laboratory Contact

 

Ms. Juanita O’Melia

 

 

ACC at various temperatures

 

Bacillus cereus and other pathogenic Bacillus spp.

 

Clostridium perfringens

 

Sulphite-reducing Clostridia

 

Salmonella spp.

 

Campylobacter spp.

 

Listeria monocytogenes (detection & enumeration)

 

Listeria spp.

 

Staphylococcus aureus

 

Staphylococcus aureus enterotoxin

 

Vibrio parahaemolyticus

 

Escherichia coli

 

Coliforms

 

Enterobacteriaceae

 

Yeast/mould counts

 

Enterobacter sakazakii

 

 

Following a review of pricing the following charges will now apply for Microbiological Testing from 02/01/1

Food Testing:

Matrix No. of tests Price € (Nett - excluding VAT)
Food Sample 1 75.00
Food Sample 2-3 150.00
Food Sample >4 225.00


Swab Testing:

Swab Type No of swabs No. of tests Price € (Nett - excluding VAT)
Enumeration 1 1-4 75.00
Detection 1 1 75.00

The prices indicated are guideline prices.

Where specific parameters are requested for particular matrices (food samples) which may require extra work, the charges may be higher.

Additional charges will be applied where chemical testing is also being carried out.

Last up dated 24/01/2014

Directions on taking food samples

 

Chemical Analysis

Back to Top

Please note the following requirements for sampling of foods for chemical analysis:

  1. Please refer to the notes section of the current Chemical Food Sampling Programme for information on the types of samples and minimum sample quantities required for each parameter.
  2. Food samples submitted for monitoring to ensure compliance with EU food laws should be sampled in compliance with the various EU Sampling Regulations. For example, for heavy metals the regulations recommend that, where possible, a sample size of at least 1 kg is taken.
  3. If a number of retail units of a product are required to make up a sample, please ensure that all units are of one batch number. Prior to analysis, all units of the sample are combined and sub-samples are tested. In the event of an unsatisfactory result being obtained, it is not possible to identify the problematic batch where a composite sample of units from different batches has been tested.
  4. When attaching adhesive labels to samples ensure that information such as ingredient lists, nutrition labelling, claims etc. is not obscured. If the sample is small in size and this is not practical, the sample may be placed in a clear plastic bag to which the label can be attached.
  5. It is a requirement of the laboratory accreditation to "ISO 17025:2005 – General Requirements for the Competence of Testing and Calibration Laboratories", that there is a contract between a customer and the laboratory. The Analysis Request Form is such a contract. For this reason, it is vital that the field "Analysis Required" is completed on the Analysis Request Form and that the required parameter(s) are specified as indicated in the programme. Entries such as "chemical" or "compositional" analysis are not sufficient.
  6. In the event that scheduled samples cannot be submitted for testing, please let the specified laboratory contact know as soon as possible so that the laboratory resources can be reallocated to other work.
  7. Laboratory contact details are provided in the Programme and also in the ‘Contact Us’ section of this website. Please phone the appropriate named contact with queries regarding test parameters or sampling. When querying a test result, the Executive Analytical Chemist who is named on the test report should be contacted.
  8. Delivery of samples to the Laboratory is required within the specified sampling periods. Please ensure that all samples for chemical testing reach the Laboratory before 3p.m. on the day of delivery.

Microbiological testing

Back to Top

Food Samples for microbiological testing

  1. Food samples which would normally be refrigerated should be stored in a refrigerator immediately and submitted to the Laboratory within 24h.
  2. Samples which would normally be refrigerated and which cannot be submitted to the Laboratory within 24h should be frozen and submitted as soon as possible thereafter.
  3. All samples must be accompanied by a fully completed Laboratory Analysis Request Form.
  4. All samples should be minimally handled prior to receipt at the Laboratory. The history of sample handling and storage may affect the microbiological results.
  5. A minimum of 150g of food sample is required for microbiological analysis.

 

Storage of samples for microbiological analysis

Back to Top

  1. Frozen foods should be frozen.
  2. Chilled/refrigerated foods should be stored between 0 and 5oC and not frozen.
  3. Dried foods, un-blown cans and foods not generally refrigerated need not be chilled but should be stored and transported at a temperature of less than 20oC
National Chemical Food Sampling Programme 2016
PDF Document
678 KB
Created 17/02/2016 Modified Wed, 23 Mar 2016 15:26:12 GMT

Natioal Food Sampling Programme-Contacts Dublin PAL
PDF Document
143KB
Created 17/02/2016 Modified Thu, 18 Feb 2016 10:35:42 GMT